You need to clean or change the battery terminals. UPS can not draw enough current through them to provide the backup. Sol: Usually it happens if battery terminals are corroded. In fact, UPS is not switching to backup mode. Quality of internal circuitry also matters.ģ- Batteries are charged but UPS is not providing any backup. Usually, it happens only if cooling fan of UPS was not working properly or UPS is placed at extremely hot place. If rectifiers or step down transformer of charger are burnt, batteries will not be charged. Clean them or change them if they are rotted due to corrosion. If they are rusty, electricity won’t flow through them. Sol: Check to make sure that battery terminals are rust free.
#HOMAGE INVERTER HTU 1005 INSTALL#
You may also install a stabilizer to fix the voltage issue.Ģ- Batteries are connected properly but not getting charged. Note that choosing wide range increases the switch over time of UPS. If that is true, choose wide range from UPS for input. Check to make sure that that is not the case. It also happens that if input voltage is too low to be acceptable, UPS does not switch over to main electricity supply. If you can not do it yourself, take it to the service centre. Sometimes, fuses of input melt resulting in no input. Sol: Make sure that input plug is connected and providing electricity to the UPS. Solution for some other problems related to Homage Power Inverters:ġ- UPS is running continuously in inverter mode despite of main electricity presence. I am recommending these based on my personal 7+ years experience with CyberPower Inverters.ĬyberPower Inverters: Review & Description
#HOMAGE INVERTER HTU 1005 PC#
Your fan capacitors, fan regulators, energy savers, PC power supply and other electronic devices will not burn randomly. Their build quality is good and their simulated sine wave current is safe for devices. Better take your power inverter to service center if it keeps giving same error over and over again.Īfter receiving thousands of complaints about Homage inverters, I shall recommend to avoid these inverters.
#HOMAGE INVERTER HTU 1005 CODE#
Each code could have different details for different model.
![homage inverter htu-1005 homage inverter htu-1005](https://i.ytimg.com/vi/_juhxpmXDpY/maxresdefault.jpg)
Note that inverter error codes are not standardized. So instead of posting abusive comments, spend time reading through comments. I have tried to explain several error codes / faults in comments section. The above power ratings should only be used as a guide.Here are the specifications of three models of Homage Inverters, Vision 500, Vision 1000 and Vision 2000, and common problems with solutions.Īdmin’s Note: Although, this post is about an old Homage inverter series, you can still ask questions related to all new & discontinued Homage Inverters in comments section below. Induction Motor running watts obtained from the National Electric Code Handbook. The starting watts for a motor are obtained by multiplying the locked rotor current by the AC voltage.ģ. The wattage required to start certain motor driven loads could be 3 to 10 times their normal running wattage. Wattage may be found on the appliance nameplate or by multiplying the AC voltage (120 volts) by the running current (amps).Ģ. This information is essential to proper inverter selection. The electrical power consumed by an electrical device is measured in watts. To support 75 amp hours of battery power, 150 amp hours of battery capacity is required.Īverage Wattage Ratings of Products Operated from Vanner InvertersĪverage Wattage Ratings of Products Operated from Vanner Inverters (Cont.)ġ. Note – if this 75 amps is drawn from the battery for one hour, 75 amp hours (AH) of battery power will be used.